TECHNICAL CHARACTERISTICS
Name of characteristics and parameters | Unit of measure | Values |
Nominal productivity of the plant on sludge | cub.m/h | 5 |
Maximum productivity of the plant on sludge | cub.m/h | 15* |
Consumption of reverse technical water, approximately | cub.m/shrift | 25 |
The characteristic of the water arriving on washing (in a cycle): | ||
- Temperature | °Ñ | +5…+80** |
- The oil content of not more than | g/kg | 1,0 |
- Content of mechanical impurities (up to 40 μm), not more | % | 5 |
Number of equipment units , including: | pieces | 4*** |
- Soil preparation unit | piece | 1 |
- Soil cleaning unit | piece | 1 |
- Water treatment unit | piece | 2 |
AC Power supply for the equipment | ||
- Voltage | V | 380 |
- Frequency | Hz | 50 |
- Fluctuations in the mains | % | ±10 |
Power consumption , not more than | kW | 110 |
Soil washing | — | possible |
The separation of liquid phases | — | possible |
Application of surfactants, chemicals | — | provided (if neccessary) |
Ability to work with a liquid material | — | available |
Ability to work with a solid material | — | available |
Possibility of continuous monitoring of explosive gases using the gas analyzer unit | — | available |
* - The performance of purifying the soil depends on the degree of contamination and the composition of the soil.
** - In order to avoid performance degradation of the plant, as well as to increase the quality of the soil purification is recommended to wash soil with water at a temperature of +60 ... + 80°C (depending on the composition of contaminated soil) using steam generator or boiler.
*** - as standard, without optional equipment.
Preparation and cleaning the soil is made in several stages, the order of which is described below.